first cut at turnon scripts for EasyTimer v2
[fw/altos] / doc / telemini.inc
index b7b26a8a261999726fa8c976bd9f4a1b05fc2a87..97bca72b462e7529998299b7430dd0884dd84218 100644 (file)
                |Apogee pyro channel connection to pyro circuit
 
                |2
-               |Apogee +
-               |Apogee pyro channel common connection to battery +
+               |Apogee +++
+               |Apogee pyro channel common connection to battery +++
 
                |3
                |Main -
                |Main pyro channel connection to pyro circuit
 
                |4
-               |Main +
-               |Main pyro channel common connection to battery +
+               |Main +++
+               |Main pyro channel common connection to battery +++
 
                |Left
                |Switch Output
 
                As described above, using an external pyro battery involves
                connecting the negative battery terminal to the flight
-               computer ground, connecting the positive battery terminal to
-               one of the igniter leads and connecting the other igniter
-               lead to the per-channel pyro circuit connection. Because
-               there is no solid ground connection to use on TeleMini, this
-               is not recommended.
+               computer ground, connecting the switched positive battery 
+               terminal to one of the igniter leads and connecting the other 
+               igniter lead to the per-channel pyro circuit connection. 
+               Because there is no solid ground connection to use on 
+               TeleMini, this is not recommended.
 
                The only available ground connection on TeleMini v3 are
                the two mounting holes next to the telemetry
@@ -75,7 +75,9 @@
 
                Connecting the positive battery terminal to the pyro
                charges must be done separate from TeleMini v3, by soldering
-               them together or using some other connector.
+               them together or using some other connector.  Note that you 
+               must include a switch in the pyro battery positive lead for
+               safety!
 
                The other lead from each pyro charge is then inserted into
                the appropriate per-pyro channel screw terminal (terminal 3 for the
                callsign settings are, you can temporarily force it
                back to the original default values (frequency
                434.550MHz, callsign N0CALL) by connecting a wire
-               between hole 3 and hole 7 on the debug connector. Hole
-               3 has the square pad around it, hole 7 is the one
+               between hole 3 and hole 6 on the debug connector. Hole
+               3 has the square pad around it, hole 6 is the one
                nearest the MS5607 baro sensor, which is a rectangular
                component with a metal cap that has two holes in it.