The TPS76133 requires at least 4.7uF of output capacitance to be
stable, and some noise was seen in the baro sensor with the 2.2uF
value.
Signed-off-by: Keith Packard <keithp@keithp.com>
)
-Element["" "0402" "C6" "2.2uF" 5.1374mm 515.00mil -0.5400mm 11.00mil 0 80 ""]
+Element["" "0402" "C6" "4.7uF" 5.1374mm 515.00mil -0.5400mm 11.00mil 0 80 ""]
(
Pad[-15.74mil -3.93mil -15.74mil 3.93mil 19.68mil 20.00mil 25.68mil "1" "1" "square"]
Pad[15.74mil -3.93mil 15.74mil 3.93mil 19.68mil 20.00mil 25.68mil "2" "2" "square"]
T 40300 42500 5 10 0 0 90 0 1
device=CAPACITOR
T 41000 42300 5 10 0 0 0 0 1
-vendor_part_number=587-3153-1-ND
+vendor_part_number=587-2787-1-ND
T 41000 42300 5 10 0 0 0 0 1
footprint=0402
T 41000 42300 5 10 0 0 0 0 1
T 41200 43100 5 10 1 1 180 0 1
refdes=C6
T 41000 42400 5 10 1 1 0 0 1
-value=2.2uF
+value=4.7uF
T 41000 42300 5 10 0 1 0 0 1
symversion=0.1
}