Replace LDO output cap with 4.7uF
authorKeith Packard <keithp@keithp.com>
Mon, 2 Dec 2013 07:25:31 +0000 (23:25 -0800)
committerKeith Packard <keithp@keithp.com>
Mon, 2 Dec 2013 07:25:31 +0000 (23:25 -0800)
commit9124eea88dad87e0f7e5fe49360759b75a935a24
treeca437b366afef426c956f335bf8c7aa6c85f3ab4
parent69727edf32abc62fd39814ddef3da43f78d67b38
Replace LDO output cap with 4.7uF

The TPS76133 requires at least 4.7uF of output capacitance to be
stable, and some noise was seen in the baro sensor with the 2.2uF
value.

Signed-off-by: Keith Packard <keithp@keithp.com>
telemini.pcb