Report igniter continuity in pad/idle mode via beeper
authorKeith Packard <keithp@keithp.com>
Sat, 10 Oct 2009 22:08:14 +0000 (15:08 -0700)
committerKeith Packard <keithp@keithp.com>
Sat, 10 Oct 2009 22:08:14 +0000 (15:08 -0700)
commit8f7ea3de7037f40b0ff462b60d503c19431ae62b
tree11a94602290e1a6ba51708a79fd3f2852e4b697d
parent5f26ad663b3f60dddc9d967206e365f45dc4acd1
Report igniter continuity in pad/idle mode via beeper

one short beep = drogue
two short beeps = main
three short beeps = both
one long warble = neither

In idle mode, it does this just once. In pad mode, it keeps testing
and reporting.

Signed-off-by: Keith Packard <keithp@keithp.com>
src/ao_report.c