altos/telefire*: Do voltage tests in decivolts instead of ADC units
[fw/altos] / src / telefire-v0.1 / ao_pins.h
index ee0ca7166c3639d45d22c54cc97c212bd7e839d9..8266589e254845f6ee2ad20fd7a77aa3ec119dd2 100644 (file)
 #define AO_STROBE_PIN          1
 #define AO_STROBE              P1_1
 
-/* test these values with real igniters */
-#define AO_PAD_RELAY_CLOSED    3524
-#define AO_PAD_NO_IGNITER      16904
-#define AO_PAD_GOOD_IGNITER    22514
+#define AO_ADC_REFERENCE_DV    33
+#define AO_PAD_R_V_BATT_BATT_SENSE     100
+#define AO_PAD_R_BATT_SENSE_GND                27
+
+#define AO_PAD_R_V_BATT_V_PYRO         100
+#define AO_PAD_R_V_PYRO_PYRO_SENSE     100
+#define AO_PAD_R_PYRO_SENSE_GND                27
+
+#define AO_PAD_R_V_PYRO_IGNITER                100
+#define AO_PAD_R_IGNITER_IGNITER_SENSE 100
+#define AO_PAD_R_IGNITER_SENSE_GND     27
 
 #define AO_PAD_ADC_PYRO                4