update info on using separate pyro batteries to encourage including a switch
[fw/altos] / doc / telemega.inc
index 55f77bc48771d6db476df1adb85c4325cdd0378e..092077e00da73e04923c77167f9e783d965e8283 100644 (file)
@@ -1,7 +1,7 @@
 == TeleMega
 
        .TeleMega Board
-       image::telemega-v1.0-top.jpg[width="5.5in"]
+       image::telemega-v1.0-top.jpg[width=400]
 
        TeleMega is a 1¼ inch by 3¼ inch circuit board. It was
        designed to easily fit in a 38mm coupler. Like TeleMetrum,
                TeleMega provides explicit support for an external pyro
                battery. All that is required is to remove the jumper
                between the lipo terminal (Bottom 3) and the pyro terminal
-               (Bottom 2). Then hook the negative pyro battery terminal to ground
-               (Bottom 1) and the positive pyro battery to the pyro battery
-               input (Bottom 2). You can then use the existing pyro screw
+               (Bottom 2). Then hook the negative pyro battery terminal to 
+               ground (Bottom 1) and the switched positive pyro battery to 
+               the pyro battery input (Bottom 2). Note that you must include
+                a switch between the pyro battery and the board for safety,
+                as the on-board power switch circuit only supports the primary
+                battery!  You can then use the existing pyro screw
                terminals to hook up all of the pyro charges.
 
        === Using Only One Battery With TeleMega