switch to 1600psi pressure sensor on test stand tf1-2019-hack
authorBdale Garbee <bdale@gag.com>
Wed, 5 Jun 2019 16:47:34 +0000 (10:47 -0600)
committerBdale Garbee <bdale@gag.com>
Wed, 5 Jun 2019 16:47:34 +0000 (10:47 -0600)
altoslib/AltosEepromRecordFireTwo.java

index e60497c360cbf2b721677e7b3def70b60db86dad..4dd61bb52e0cd76499099a69a00064cd7af1a614 100644 (file)
@@ -48,12 +48,12 @@ public class AltosEepromRecordFireTwo extends AltosEepromRecord {
        public static double adc_to_pa(int adc) {
 
 //             /* 1600psi sensor measured 2019.04.30, these values based on that */
-//             double ADC_MIN = 405;
-//             double ADC_SLOPE = 1.95;
+               double ADC_MIN = 405;
+               double ADC_SLOPE = 1.95;
 
                /* 2500psi sensor measured 2019.04.30, these values based on that */
-               double ADC_MIN = 392;
-               double ADC_SLOPE = 0.46;        /* adc counts per psi */
+//             double ADC_MIN = 392;
+//             double ADC_SLOPE = 0.46;        /* adc counts per psi */
 
                /* sensor is asserted to be linear 0 - max psi over ADC_MIN to ADC_MAX */
                double raw = adc;