altos: Timers clock base depends on perhipheral bus prescalers too
authorKeith Packard <keithp@keithp.com>
Sat, 2 Jun 2012 02:35:33 +0000 (19:35 -0700)
committerKeith Packard <keithp@keithp.com>
Sat, 2 Jun 2012 02:35:33 +0000 (19:35 -0700)
For some weird reason, a non-unity perhipheral bus clock scaler
affects the base of the various timers; this left the 100Hz tick
running at 200Hz.

Signed-off-by: Keith Packard <keithp@keithp.com>