of less than that value.
====
-Flight Time:: Time since boost was detected. Select a value and choose
-whether to activate the pyro channel before or after that amount of
-time.
+Flight Time:: Time since launch. Select a value and choose whether to
+activate the pyro channel before or after that amount of time.
+
+[WARNING]
+Firmware versions older than 1.8.6 have a bug which resets the time
+since launch to zero each time a motor starts burning. Update firmware
+to get the correct behavior.
Ascending:: A deprecated configuration value which was the same as
setting Ascent rate > 0. Existing configurations using this will be
After Motor:: The flight software counts each time the rocket starts
accelerating and then decelerating (presumably due to a motor or
motors burning). Use this value for multi-staged or multi-airstart
-launches.
+launches. As of version 1.8.6 firmware, this checks to make sure at
+least this many motors have burned. Before version 1.8.6, this checked
+to make sure that exactly this many motors had burned.
Delay:: Once the other parameters all become true, a timer is
started for the specified amount of time. While the timer is running,