-Delay:: This value doesn't perform any checks,
-instead it inserts a delay between the time
-when the other parameters become true and when
-the pyro channel is activated.
+After Motor:: The flight software counts each time the rocket starts
+accelerating and then decelerating (presumably due to a motor or
+motors burning). Use this value for multi-staged or multi-airstart
+launches. As of version 1.8.6 firmware, this checks to make sure at
+least this many motors have burned. Before version 1.8.6, this checked
+to make sure that exactly this many motors had burned.
+
+Delay:: Once the other parameters all become true, a timer is
+started for the specified amount of time. While the timer is running,
+the other parameters are checked repeatedly and if any of them become
+false, then the pyro channel is disabled and will not fire. If the
+timer expires and all of the other parameters have remained true for
+the entire time, then the pyro channel is fired.