Version 1.9.6.2
[fw/altos] / doc / easymini-device.inc
index b7af82f2ee8f28506e650c454cff7d3afe289cc5..841f7a3ee6a7966a58ddba1ee8bb63104478f68b 100644 (file)
                |Main pyro channel connection to pyro circuit
              
                |Top 2
                |Main pyro channel connection to pyro circuit
              
                |Top 2
-               |Main +
-               |Main pyro channel common connection to battery +
+               |Main +++
+               |Main pyro channel common connection to battery +++
              
                |Top 3
              
                |Top 3
-               |Battery +
+               |Battery +++
                |Positive external battery terminal
              
                |Top 4
                |Positive external battery terminal
              
                |Top 4
@@ -47,8 +47,8 @@
                |Apogee pyro channel connection to pyro circuit
              
                |Bottom 2
                |Apogee pyro channel connection to pyro circuit
              
                |Bottom 2
-               |Apogee +
-               |Apogee pyro channel common connection to battery +
+               |Apogee +++
+               |Apogee pyro channel common connection to battery +++
              
                |Bottom 3
                |Switch Output
              
                |Bottom 3
                |Switch Output
@@ -97,7 +97,7 @@
                Connecting the switched positive battery terminal to the pyro
                charges must be done separate from EasyMini, by soldering
                them together or using some other connector.  Note that for
                Connecting the switched positive battery terminal to the pyro
                charges must be done separate from EasyMini, by soldering
                them together or using some other connector.  Note that for
-               safety, you should put a switch between the pyro battery and
+               safety, you must put a switch between the pyro battery and
                the rest of the circuit!
 
                The other lead from each pyro charge is then inserted into
                the rest of the circuit!
 
                The other lead from each pyro charge is then inserted into