fix DigiKey part numbers on C7, C14, C15, and C16, all of which were wrong
authorBdale Garbee <bdale@gag.com>
Sun, 1 Mar 2009 19:52:49 +0000 (12:52 -0700)
committerBdale Garbee <bdale@gag.com>
Sun, 1 Mar 2009 19:52:49 +0000 (12:52 -0700)
telemetrum.sch

index e7ffb5275574ca52daadd0b9b0bcf23a34a89b64..cf5846bc29d74119b37cc14a21d928ee25313662 100644 (file)
@@ -1163,7 +1163,7 @@ footprint=0402
 T 48800 67400 5 10 1 1 0 0 1
 value=4.7uF
 T 48800 67300 5 10 0 1 0 0 1
-digikey=399-3027-1-ND
+digikey=PCC2475CT-ND
 }
 N 48600 69100 48600 68200 4
 C 48400 69100 1 0 0 5V-plus-1.sym
@@ -1227,7 +1227,7 @@ footprint=0402
 T 45200 70600 5 10 1 1 0 0 1
 value=0.22uF
 T 44600 70200 5 10 0 1 0 0 1
-digikey=490-1316-1-ND
+digikey=587-1228-1-ND
 }
 C 43500 67300 1 90 0 capacitor.sym
 {
@@ -1242,7 +1242,7 @@ footprint=0402
 T 42600 67400 5 10 1 1 0 0 1
 value=4.7uF
 T 43500 67300 5 10 0 1 0 0 1
-digikey=399-3027-1-ND
+digikey=PCC2475CT-ND
 }
 N 46500 69100 51700 69100 4
 N 44500 70000 44500 70400 4
@@ -1341,7 +1341,7 @@ footprint=0402
 T 47800 67400 5 10 1 1 0 0 1
 value=4.7uF
 T 47800 67300 5 10 0 1 0 0 1
-digikey=587-1453-1-ND
+digikey=PCC2475CT-ND
 }
 N 46500 68700 47600 68700 4
 N 47600 68700 47600 68200 4