Move reset_n to LPC PIO0_4, a true open-drain pin
authorKeith Packard <keithp@keithp.com>
Sat, 21 Aug 2021 04:20:59 +0000 (21:20 -0700)
committerKeith Packard <keithp@keithp.com>
Sat, 21 Aug 2021 04:20:59 +0000 (21:20 -0700)
There are two pins on the LPC which operate in true open-drain mode,
PIO0_4 and PIO0_5. Use one of these instead of one of the 'pseudo open
drain' pins to make sure reset works correctly.

Signed-off-by: Keith Packard <keithp@keithp.com>
telemetrum.sch

index a0825baa4aa8ca4134b4fc7bbe84aea2e0b77cd5..d69589c6584f9a2df4e00ba5e899534ae6084073 100644 (file)
@@ -2063,8 +2063,8 @@ T 65200 65300 5 10 0 1 0 0 1
 footprint=0603
 }
 N 63500 65100 63500 64700 4
-N 50600 63500 51800 63500 4
+N 50600 71100 51800 71100 4
 {
-T 51800 63550 5 10 1 1 0 6 1
+T 51800 71150 5 10 1 1 0 6 1
 netname=reset_n
 }