snapshot after return from Brussels
[hw/telemega] / megametrum.sch
index f5e5daa06cfe5335e114fde30ef9f4a93be2f325..043be2ffbf25eed666a2acd55f839362af981eea 100644 (file)
@@ -622,49 +622,49 @@ loadstatus=smt
 }
 C 82100 72900 1 0 0 3.3V-plus.sym
 N 82300 72900 82300 72700 4
-C 80600 71800 1 90 0 capacitor.sym
+C 81900 71800 1 90 0 capacitor.sym
 {
-T 79900 72000 5 10 0 0 90 0 1
+T 81200 72000 5 10 0 0 90 0 1
 device=CAPACITOR
-T 80950 72600 5 10 1 1 180 0 1
+T 81550 72600 5 10 1 1 180 0 1
 refdes=C34
-T 79700 72000 5 10 0 0 90 0 1
+T 81000 72000 5 10 0 0 90 0 1
 symversion=0.1
-T 80600 71795 5 10 0 1 90 0 1
+T 81900 71795 5 10 0 1 90 0 1
 footprint=0402
-T 80600 71900 5 10 1 1 0 0 1
+T 81000 71900 5 10 1 1 0 0 1
 value=0.001uF
-T 80600 71800 5 10 0 0 0 0 1
+T 81900 71800 5 10 0 0 0 0 1
 vendor_part_number=445-2651-1-ND
-T 80600 71800 5 10 0 0 0 0 1
+T 81900 71800 5 10 0 0 0 0 1
 vendor=digikey
-T 80600 71800 5 10 0 1 0 0 1
+T 81900 71800 5 10 0 1 0 0 1
 loadstatus=smt
 }
-N 80400 72800 82300 72800 4
+N 81700 72800 82300 72800 4
 N 82300 71000 82300 71800 4
-N 80400 70600 82300 70600 4
-C 80900 70800 1 0 0 capacitor.sym
+N 81700 70600 82300 70600 4
+C 80600 70800 1 0 0 capacitor.sym
 {
-T 81100 71500 5 10 0 0 0 0 1
+T 80800 71500 5 10 0 0 0 0 1
 device=CAPACITOR
-T 81200 71500 5 10 1 1 180 0 1
+T 80900 71400 5 10 1 1 180 0 1
 refdes=C35
-T 81100 71700 5 10 0 0 0 0 1
+T 80800 71700 5 10 0 0 0 0 1
 symversion=0.1
-T 81900 71500 5 10 1 1 180 0 1
+T 81600 71400 5 10 1 1 180 0 1
 value=22pF
-T 80900 70800 5 10 0 0 90 0 1
+T 80600 70800 5 10 0 0 90 0 1
 vendor_part_number=490-1283-1-ND
-T 80900 70800 5 10 0 0 90 0 1
+T 80600 70800 5 10 0 0 90 0 1
 footprint=0402
-T 80900 70800 5 10 0 0 0 0 1
+T 80600 70800 5 10 0 0 0 0 1
 vendor=digikey
-T 80900 70800 5 10 0 1 0 0 1
+T 80600 70800 5 10 0 1 0 0 1
 loadstatus=smt
 }
-N 79500 71000 80900 71000 4
-N 81800 71000 82300 71000 4
+N 79500 71000 80600 71000 4
+N 81500 71000 82300 71000 4
 T 80800 49200 9 10 1 0 0 0 2
   SMA is optional
 default is wire whip
@@ -809,12 +809,12 @@ T 74300 63400 9 10 1 0 0 0 2
 As of SkyTraq version 0.3, pin 
 19 is attached to system GND
 N 73500 64300 74700 64300 4
-N 75500 64300 80400 64300 4
+N 75500 64300 81700 64300 4
 {
 T 79700 64400 5 10 1 1 0 0 1
 netname=gnd_rf
 }
-N 80400 64300 80400 71800 4
+N 81700 64300 81700 71800 4
 C 64600 43200 1 270 0 capacitor.sym
 {
 T 65300 43000 5 10 0 0 270 0 1
@@ -892,7 +892,7 @@ loadstatus=smt
 T 42300 68700 5 10 0 1 0 0 1
 vendor_part_number=W25Q64CVSSIG-ND
 }
-N 80400 72700 80400 72800 4
+N 81700 72700 81700 72800 4
 T 83200 70700 9 10 1 0 0 0 1
 GPS
 C 48700 68800 1 0 0 MMA6556.sym
@@ -3185,3 +3185,15 @@ N 70100 53900 68900 53900 4
 T 68900 54000 5 10 1 1 0 0 1
 netname=reset_n
 }
+C 80000 72100 1 0 0 antenna.sym
+{
+T 80200 72500 5 10 0 0 0 0 1
+device=CAPACITOR
+T 80200 72300 5 10 1 1 0 0 1
+refdes=A1
+T 80200 72700 5 10 0 0 0 0 1
+symversion=0.1
+T 80000 72100 5 10 0 1 0 0 1
+footprint=GP1575.18
+}
+N 80100 71000 80100 72100 4