rationalize part values vs preferred-parts
authorBdale Garbee <bdale@gag.com>
Fri, 18 Sep 2020 23:19:46 +0000 (17:19 -0600)
committerBdale Garbee <bdale@gag.com>
Fri, 18 Sep 2020 23:19:46 +0000 (17:19 -0600)
fctester.sch

index b72f643f0743235216f34538ba3de4c2ffd2494a..6a0ee40fbe524033af619c25d231d63cfb4e6739 100644 (file)
@@ -1,4 +1,4 @@
-v 20130925 2
+v 20200604 2
 C 75300 65300 1 0 0 gnd.sym
 N 75400 65600 75400 66000 4
 T 72400 52800 9 30 1 0 0 0 1
@@ -1256,7 +1256,7 @@ vendor=digikey
 T 67800 66000 5 10 1 1 180 0 1
 refdes=C10
 T 67400 65350 5 10 1 1 0 0 1
-value=0.01uF
+value=10nF
 }
 C 70100 64800 1 0 0 gnd.sym
 C 68200 65000 1 0 0 LT1787.sym
@@ -1373,7 +1373,7 @@ footprint=282834-4
 T 77000 60600 5 10 0 1 0 0 1
 device=CONNECTOR
 T 77000 60600 5 10 0 1 0 0 1
-value=Terminal-4
+value=4screws
 T 77000 60600 5 10 0 1 0 0 1
 loadstatus=throughhole
 T 77000 60600 5 10 0 1 0 0 1
@@ -1390,7 +1390,7 @@ footprint=282834-4
 T 75100 59200 5 10 0 1 0 0 1
 device=CONNECTOR
 T 75100 59200 5 10 0 1 0 0 1
-value=Terminal-4
+value=4screws
 T 75100 59200 5 10 0 1 0 0 1
 loadstatus=throughhole
 T 75100 59200 5 10 0 1 0 0 1