Clean up ground plane, flip debug connector, move passives away from holes
authorKeith Packard <keithp@keithp.com>
Wed, 5 Feb 2014 07:24:47 +0000 (23:24 -0800)
committerKeith Packard <keithp@keithp.com>
Wed, 5 Feb 2014 07:24:47 +0000 (23:24 -0800)
commit9d1be2ade9e62ffb027c53e0a85591fcbb0bd9ad
tree0438a70d11d512e2be37257f8048e01ddf275a7c
parentfd0c8c33b9e6ce9f3d896f5575fa8f394965e940
Clean up ground plane, flip debug connector, move passives away from holes

First, moved various voltage divider resistors away from the mounting
holes to keep them from getting bashed.

Next, shuffled wiring around to improve ground connectivity

Last, flipped the debug connector over so that pin 1 was ground
instead of pin 6.

Signed-off-by: Keith Packard <keithp@keithp.com>
easymini.pcb
easymini.sch