X-Git-Url: https://git.gag.com/?p=fw%2Faltos;a=blobdiff_plain;f=doc%2Ftelemini.inc;fp=doc%2Ftelemini.inc;h=03732b2af2ac4ee03d7dfed70845d42aeabc6b47;hp=b7b26a8a261999726fa8c976bd9f4a1b05fc2a87;hb=5b1bd4f87f682c1956e173a27414ceb076b20ceb;hpb=366c1422f6d34c8f616dc95c2767d01c4f53f581 diff --git a/doc/telemini.inc b/doc/telemini.inc index b7b26a8a..03732b2a 100644 --- a/doc/telemini.inc +++ b/doc/telemini.inc @@ -62,11 +62,11 @@ As described above, using an external pyro battery involves connecting the negative battery terminal to the flight - computer ground, connecting the positive battery terminal to - one of the igniter leads and connecting the other igniter - lead to the per-channel pyro circuit connection. Because - there is no solid ground connection to use on TeleMini, this - is not recommended. + computer ground, connecting the switched positive battery + terminal to one of the igniter leads and connecting the other + igniter lead to the per-channel pyro circuit connection. + Because there is no solid ground connection to use on + TeleMini, this is not recommended. The only available ground connection on TeleMini v3 are the two mounting holes next to the telemetry @@ -75,7 +75,9 @@ Connecting the positive battery terminal to the pyro charges must be done separate from TeleMini v3, by soldering - them together or using some other connector. + them together or using some other connector. Note that you + must include a switch in the pyro battery positive lead for + safety! The other lead from each pyro charge is then inserted into the appropriate per-pyro channel screw terminal (terminal 3 for the