altosui: Allow TM config connection to be canceled.
[fw/altos] / altosui / AltosSerial.java
index a8ba66bde009acc49f7c1c03d71741e7e7110fd2..88b38bb176f01ad00db321de36fb698d2c14019c 100644 (file)
@@ -25,6 +25,11 @@ import java.lang.*;
 import java.io.*;
 import java.util.concurrent.*;
 import java.util.*;
+import java.awt.*;
+import java.awt.event.*;
+import javax.swing.*;
+import javax.swing.filechooser.FileNameExtensionFilter;
+import javax.swing.table.*;
 
 import libaltosJNI.*;
 
@@ -36,7 +41,7 @@ import libaltosJNI.*;
 
 public class AltosSerial implements Runnable {
 
-       static List<String> devices_opened = Collections.synchronizedList(new LinkedList<String>());
+       static java.util.List<String> devices_opened = Collections.synchronizedList(new LinkedList<String>());
 
        AltosDevice device;
        SWIGTYPE_p_altos_file altos;
@@ -52,6 +57,7 @@ public class AltosSerial implements Runnable {
        static boolean debug;
        boolean remote;
        LinkedList<String> pending_output = new LinkedList<String>();
+       Frame frame;
 
        static void set_debug(boolean new_debug) {
                debug = new_debug;
@@ -126,6 +132,59 @@ public class AltosSerial implements Runnable {
                }
        }
 
+       boolean         abort;
+       JDialog         timeout_dialog;
+       boolean timeout_started = false;
+
+       private void stop_timeout_dialog() {
+               System.out.printf("stop_timeout_dialog\n");
+               Runnable r = new Runnable() {
+                               public void run() {
+                                       if (timeout_dialog != null)
+                                               timeout_dialog.setVisible(false);
+                               }
+                       };
+               SwingUtilities.invokeLater(r);
+       }
+
+       private void start_timeout_dialog_internal() {
+               System.out.printf("Creating timeout dialog\n");
+               Object[] options = { "Cancel" };
+
+               JOptionPane     pane = new JOptionPane();
+               pane.setMessage(String.format("Connecting to %s", device.getPath()));
+               pane.setOptions(options);
+               pane.setInitialValue(null);
+
+               timeout_dialog = pane.createDialog(frame, "Connecting...");
+
+               timeout_dialog.setVisible(true);
+
+               Object o = pane.getValue();
+               if (o == null)
+                       return;
+               if (options[0].equals(o))
+                       abort = true;
+       }
+
+       private boolean check_timeout() {
+               if (!timeout_started && frame != null) {
+                       timeout_started = true;
+                       System.out.printf("Starting timeout dialog\n");
+                       if (SwingUtilities.isEventDispatchThread()) {
+                               start_timeout_dialog_internal();
+                       } else {
+                               Runnable r = new Runnable() {
+                                               public void run() {
+                                                       start_timeout_dialog_internal();
+                                               }
+                                       };
+                               SwingUtilities.invokeLater(r);
+                       }
+               }
+               return abort;
+       }
+
        public void flush_input() {
                flush_output();
                boolean got_some;
@@ -156,10 +215,21 @@ public class AltosSerial implements Runnable {
 
        public String get_reply(int timeout) throws InterruptedException {
                flush_output();
-               AltosLine line = reply_queue.poll(timeout, TimeUnit.MILLISECONDS);
-               if (line == null)
-                       return null;
-               return line.line;
+               if (remote) {
+                       timeout = 300;
+                       System.out.printf("Doing remote timout\n");
+               }
+               abort = false;
+               timeout_started = false;
+               for (;;) {
+                       AltosLine line = reply_queue.poll(timeout, TimeUnit.MILLISECONDS);
+                       if (line != null) {
+                               stop_timeout_dialog();
+                               return line.line;
+                       }
+                       if (!remote || check_timeout())
+                               return null;
+               }
        }
 
        public void add_monitor(LinkedBlockingQueue<AltosLine> q) {
@@ -289,16 +359,25 @@ public class AltosSerial implements Runnable {
        public void stop_remote() {
                if (debug)
                        System.out.printf("stop remote\n");
-               flush_input();
-               printf ("~");
-               flush_output();
+               try {
+                       flush_input();
+               } finally {
+                       System.out.printf("Sending tilde\n");
+                       printf ("~\n");
+                       flush_output();
+               }
                remote = false;
        }
 
+       public void set_frame(Frame in_frame) {
+               frame = in_frame;
+       }
+
        public AltosSerial(AltosDevice in_device) throws FileNotFoundException, AltosSerialInUseException {
                device = in_device;
                line = "";
                monitor_mode = false;
+               frame = null;
                telemetry = Altos.ao_telemetry_full;
                monitors = new LinkedList<LinkedBlockingQueue<AltosLine>> ();
                reply_queue = new LinkedBlockingQueue<AltosLine> ();