4         image::telemini-v1-top.jpg[width="5.5in"]
5
6         TeleMini v1.0 is ½ inches by 1½ inches.  It was
7         designed to fit inside an 18mm air-frame tube, but using it in
8         a tube that small in diameter may require some creativity in
9         mounting and wiring to succeed!  Since there is no
10         accelerometer, TeleMini can be mounted in any convenient
11         orientation.  The default ¼ wave UHF wire antenna attached to
12         the center of one end of the board is about 7 inches long. Two
13         wires for the power switch are connected to holes in the
14         middle of the board. Screw terminals for the e-matches for
15         apogee and main ejection charges depart from the other end of
16         the board, meaning an ideal “simple” avionics bay for TeleMini
17         should have at least 9 inches of interior length.
18
19         === TeleMini v1.0 Screw Terminals
20
21                 TeleMini v1.0 has four screw terminals on the end of the
22                 board opposite the telemetry antenna. Two are for the apogee
23                 and two are for main igniter circuits. There are also wires
24                 soldered to the board for the power switch.  Using the
25                 picture above and starting from the top for the terminals
26                 and from the left for the power switch wires, the
27                 connections are as follows:
28
29                 .TeleMini v1.0 Screw Terminals
30                 [options="header",grid="all",cols="2,3,10"]
31                 |====
32                 |Terminal #|Terminal Name|Description
33
34                 |1
35                 |Apogee -
36                 |Apogee pyro channel connection to pyro circuit
37
38                 |2
39                 |Apogee +
40                 |Apogee pyro channel common connection to battery +
41
42                 |3
43                 |Main -
44                 |Main pyro channel connection to pyro circuit
45
46                 |4
47                 |Main +
48                 |Main pyro channel common connection to battery +
49
50                 |Left
51                 |Switch Output
52                 |Switch connection to flight computer
53
54                 |Right
55                 |Switch Input
56                 |Switch connection to positive battery terminal
57                 |====
58
59         === Using a Separate Pyro Battery with TeleMini v1.0
60
61                 As described above, using an external pyro battery involves
62                 connecting the negative battery terminal to the flight
63                 computer ground, connecting the positive battery terminal to
64                 one of the igniter leads and connecting the other igniter
65                 lead to the per-channel pyro circuit connection. Because
66                 there is no solid ground connection to use on TeleMini, this
67                 is not recommended.
68
69                 The only available ground connection on TeleMini v1.0 are
70                 the two mounting holes next to the telemetry
71                 antenna. Somehow connect a small piece of wire to one of
72                 those holes and hook it to the negative pyro battery terminal.
73
74                 Connecting the positive battery terminal to the pyro
75                 charges must be done separate from TeleMini v1.0, by soldering
76                 them together or using some other connector.
77
78                 The other lead from each pyro charge is then inserted into
79                 the appropriate per-pyro channel screw terminal (terminal 3 for the
80                 Main charge, terminal 1 for the Apogee charge).
81
82         === Using an Active Switch with TeleMini v1.0
83
84                 As explained above, an external active switch requires three
85                 connections, one to the positive battery terminal, one to
86                 the flight computer positive input and one to ground. Again,
87                 because TeleMini doesn't have any good ground connection,
88                 this is not recommended.
89
90                 The positive battery terminal is available on the Right
91                 power switch wire, the positive flight computer input is on