78d9133acd73759a26cc87483373dd345a894903
[fw/altos] / doc / handling.inc
1 [appendix]
2 == Handling Precautions
3
4         All Altus Metrum products are sophisticated electronic devices.
5         When handled gently and properly installed in an air-frame, they
6         will deliver impressive results.  However, as with all electronic
7         devices, there are some precautions you must take.
8
9         The Lithium Polymer rechargeable batteries have an
10         extraordinary power density.  This is great because we can fly with
11         much less battery mass than if we used alkaline batteries or previous
12         generation rechargeable batteries... but if they are punctured
13         or their leads are allowed to short, they can and will release their
14         energy very rapidly!
15         Thus we recommend that you take some care when handling our batteries
16         and consider giving them some extra protection in your air-frame.  We
17         often wrap them in suitable scraps of closed-cell packing foam before
18         strapping them down, for example.
19
20         The barometric sensors used on all of our flight computers are
21         sensitive to sunlight.  In normal mounting situations, the baro sensor
22         and all of the other surface mount components
23         are “down” towards whatever the underlying mounting surface is, so
24         this is not normally a problem.  Please consider this when designing an
25         installation in an air-frame with a see-through plastic payload bay.  It
26         is particularly important to
27         consider this with TeleMini v1.0, both because the baro sensor is on the
28         “top” of the board, and because many model rockets with payload bays
29         use clear plastic for the payload bay!  Replacing these with an opaque
30         cardboard tube, painting them, or wrapping them with a layer of masking
31         tape are all reasonable approaches to keep the sensor out of direct
32         sunlight.
33
34         The barometric sensor sampling port must be able to “breathe”,
35         both by not being covered by foam or tape or other materials that might
36         directly block the hole on the top of the sensor, and also by having a
37         suitable static vent to outside air.
38
39         As with all other rocketry electronics, Altus Metrum altimeters must
40         be protected from exposure to corrosive motor exhaust and ejection
41         charge gasses.