Imported Upstream version 2.5.0p2
[debian/amanda] / man / amlabel.8
index a9a965cfa1c6d1b49095309d650e885de77230d8..4a77231ee59836182e9c1d26b82d2ee332a60e5c 100644 (file)
 .IP "\\$1" \\$2
 ..
 .TH "AMLABEL" 8 "" "" ""
-.SH NAME
-amlabel \- label an Amanda tape
+.SH "NAME"
+amlabel - label an Amanda tape
 .SH "SYNOPSIS"
-.ad l
-.hy 0
 .HP 8
-\fBamlabel\fR [\-f] \fIconfig\fR \fIlabel\fR [\fIslot\fR\ \fIslot\fR]
-.ad
-.hy
-
+\fBamlabel\fR [-f] \fIconfig\fR \fIlabel\fR [\fIslot\fRĀ \fIslot\fR]
 .SH "DESCRIPTION"
-
 .PP
-All \fBAmanda\fR tapes must be pre\-labeled before they are used\&. \fBAmanda\fR verifies the label in \fBamdump\fR and \fBamflush\fR before writing to make sure the proper tape is loaded\&.
-
+All
+\fBAmanda\fR
+tapes must be pre-labeled before they are used.
+\fBAmanda\fR
+verifies the label in
+\fBamdump\fR
+and
+\fBamflush\fR
+before writing to make sure the proper tape is loaded.
 .PP
-\fBAmlabel\fR writes an \fBAmanda\fR label on the tape in the device specified by the \fBamanda\&.conf\fR file in /usr/local/etc/amanda/\fBconfig\fR\&. \fBLabel\fR may be any string that does not contain whitespace and that matches the \fBamanda\&.conf\fR  \fBlabelstr\fR regular expression option\&. It is up to the system administrator to define a naming convention\&.
-
+\fBAmlabel\fR
+writes an
+\fBAmanda\fR
+label on the tape in the device specified by the
+\fBamanda.conf\fR
+file in /usr/local/etc/amanda/\fBconfig\fR.
+\fBLabel\fR
+may be any string that does not contain whitespace and that matches the
+\fBamanda.conf\fR\fBlabelstr\fR
+regular expression option. It is up to the system administrator to define a naming convention.
 .PP
-\fBAmlabel\fR appends the new tape to the \fBtapelist\fR file so it will be used by \fBAmanda\fR before it reuses any other tapes\&. When you \fBamlabel\fR multiple tapes, they will be used in the order you \fBamlabel\fR them\&.
-
+\fBAmlabel\fR
+appends the new tape to the
+\fBtapelist\fR
+file so it will be used by
+\fBAmanda\fR
+before it reuses any other tapes. When you
+\fBamlabel\fR
+multiple tapes, they will be used in the order you
+\fBamlabel\fR
+them.
 .PP
-\fBAmlabel\fR will not write the label if the tape contains an active \fBAmanda\fR tape or if the label specified is on an active tape\&. The \fB\-f\fR (force) flag bypasses these verifications\&.
-
+\fBAmlabel\fR
+will not write the label if the tape contains an active
+\fBAmanda\fR
+tape or if the label specified is on an active tape. The
+\fB-f\fR
+(force) flag bypasses these verifications.
 .PP
-An optional \fBslot\fR may be specified after the tape label\&. If a tape changer is in use, \fBamlabel\fR will label the tape in the specified slot instead of the currently loaded tape\&.
-
+An optional
+\fBslot\fR
+may be specified after the tape label. If a tape changer is in use,
+\fBamlabel\fR
+will label the tape in the specified slot instead of the currently loaded tape.
 .PP
-See the \fBamanda\fR(8) man page for more details about \fBAmanda\fR\&.
-
+See the
+\fBamanda\fR(8)
+man page for more details about
+\fBAmanda\fR.
 .SH "EXAMPLE"
-
 .PP
-Write an \fBAmanda\fR label with the string "DMP000" on the tape loaded in the device named in the \fBtapedev\fR option in /usr/local/etc/amanda/daily/amanda\&.conf:
+Write an
+\fBAmanda\fR
+label with the string "DMP000" on the tape loaded in the device named in the
+\fBtapedev\fR
+option in /usr/local/etc/amanda/daily/amanda.conf:
 .nf
 
 % amlabel daily DMP000 
 .fi
-
 .PP
 Label the tape in slot 3 of the currently configured tape changer with the string "DMP003":
 .nf
 
 % amlabel daily DMP003 slot 3 
 .fi
-
 .SH "MESSAGES"
-
 .TP
 label \fBlabel\fR doesn't match labelstr \fBstr\fR
-Label \fBlabel\fR on the command line does not match the \fBlabelstr\fR regular expression \fBstr\fR from \fBamanda\&.conf\fR\&.
-
+Label
+\fBlabel\fR
+on the command line does not match the
+\fBlabelstr\fR
+regular expression
+\fBstr\fR
+from
+\fBamanda.conf\fR.
 .TP
 label \fBlabel\fR already on a tape
-Label \fBlabel\fR is already listed as an active \fBAmanda\fR tape\&.
-
+Label
+\fBlabel\fR
+is already listed as an active
+\fBAmanda\fR
+tape.
 .TP
 no tpchanger specified in \fBpath\fR , so slot command invalid
-The command line has the \fBslot\fR parameter but the \fBamanda\&.conf\fR file in \fBpath\fR does not have a tape changer configured\&.
-
+The command line has the
+\fBslot\fR
+parameter but the
+\fBamanda.conf\fR
+file in
+\fBpath\fR
+does not have a tape changer configured.
 .TP
 reading label \fBlabel\fR, tape is in another amanda configuration
-This tape appears to be a valid \fBAmanda\fR tape, but label does not match \fBlabelstr\fR for this configuration so it is probably part of a different \fBAmanda\fR configuration\&.
-
+This tape appears to be a valid
+\fBAmanda\fR
+tape, but label does not match
+\fBlabelstr\fR
+for this configuration so it is probably part of a different
+\fBAmanda\fR
+configuration.
 .TP
 reading label \fBlabel\fR, tape is active
-Tape \fBlabel\fR appears to already be part of this \fBAmanda\fR configuration and active, i\&.e\&. has valid data on it\&.
-
+Tape
+\fBlabel\fR
+appears to already be part of this
+\fBAmanda\fR
+configuration and active, i.e. has valid data on it.
 .TP
-no label found, are you sure \fBtape\fR is non\-rewinding?
-While checking that the label was written correctly, \fBamlabel\fR got an error that might be caused by mis\-configuring \fBAmanda\fR with a rewinding tape device name instead of a non\-rewinding device name for \fBtape\&.\fR
-
+no label found, are you sure \fBtape\fR is non-rewinding?
+While checking that the label was written correctly,
+\fBamlabel\fR
+got an error that might be caused by mis-configuring
+\fBAmanda\fR
+with a rewinding tape device name instead of a non-rewinding device name for
+\fBtape.\fR
 .SH "AUTHOR"
-
 .PP
-James da Silva, <jds@amanda\&.org>: Original text
-
+James da Silva,
+<jds@amanda.org>: Original text
 .PP
-Stefan G\&. Weichinger, <sgw@amanda\&.org>, maintainer of the \fBAmanda\fR\-documentation: XML\-conversion
-
+Stefan G. Weichinger,
+<sgw@amanda.org>, maintainer of the
+\fBAmanda\fR-documentation: XML-conversion
 .SH "SEE ALSO"
-
 .PP
-\fBamanda\fR(8)  \fBamdump\fR(8)  \fBamflush\fR(8)
+\fBamanda\fR(8)\fBamdump\fR(8)\fBamflush\fR(8)