From 50e7c1aa99e8fd35550707f1403261f1cd692ac8 Mon Sep 17 00:00:00 2001 From: Bdale Garbee Date: Wed, 5 Jun 2019 10:47:34 -0600 Subject: [PATCH] switch to 1600psi pressure sensor on test stand --- altoslib/AltosEepromRecordFireTwo.java | 8 ++++---- 1 file changed, 4 insertions(+), 4 deletions(-) diff --git a/altoslib/AltosEepromRecordFireTwo.java b/altoslib/AltosEepromRecordFireTwo.java index e60497c3..4dd61bb5 100644 --- a/altoslib/AltosEepromRecordFireTwo.java +++ b/altoslib/AltosEepromRecordFireTwo.java @@ -48,12 +48,12 @@ public class AltosEepromRecordFireTwo extends AltosEepromRecord { public static double adc_to_pa(int adc) { // /* 1600psi sensor measured 2019.04.30, these values based on that */ -// double ADC_MIN = 405; -// double ADC_SLOPE = 1.95; + double ADC_MIN = 405; + double ADC_SLOPE = 1.95; /* 2500psi sensor measured 2019.04.30, these values based on that */ - double ADC_MIN = 392; - double ADC_SLOPE = 0.46; /* adc counts per psi */ +// double ADC_MIN = 392; +// double ADC_SLOPE = 0.46; /* adc counts per psi */ /* sensor is asserted to be linear 0 - max psi over ADC_MIN to ADC_MAX */ double raw = adc; -- 2.47.2