From 5cd91e769885d2f9a13afcdc390f232fb015e267 Mon Sep 17 00:00:00 2001 From: Bdale Garbee Date: Mon, 23 Jan 2023 12:21:03 -0700 Subject: [PATCH] increase DC sampling resistors to stay within resistor power limit --- csm84clio.sch | 14 ++++++++------ 1 file changed, 8 insertions(+), 6 deletions(-) diff --git a/csm84clio.sch b/csm84clio.sch index d3fb7e0..9b19fe8 100644 --- a/csm84clio.sch +++ b/csm84clio.sch @@ -3752,9 +3752,10 @@ N 74700 72000 75100 72000 4 N 76000 72000 78900 72000 4 N 78400 72000 78400 68800 4 C 76800 70800 1 0 0 gnd.sym -T 73500 72600 9 10 1 0 0 0 2 +T 73500 72600 9 10 1 0 0 0 3 DC voltage to match -pneumatic valves +pneumatic valves. Note +that C13 is rated 35V. C 45100 69700 1 0 0 3.3V-plus.sym C 45200 68700 1 0 0 gnd.sym N 45300 69000 45400 69000 4 @@ -3854,7 +3855,7 @@ footprint=0402 T 79100 71600 5 10 1 1 0 0 1 refdes=R135 T 79100 71400 5 10 1 1 0 0 1 -value=10k +value=100k } C 79000 70200 1 90 0 resistor.sym { @@ -3865,7 +3866,7 @@ footprint=0402 T 79100 70700 5 10 1 1 0 0 1 refdes=R136 T 79100 70500 5 10 1 1 0 0 1 -value=1k +value=10k } C 78800 69900 1 0 0 gnd.sym N 78900 71100 81000 71100 4 @@ -3887,10 +3888,11 @@ T 80100 70400 5 10 1 1 0 0 1 value=0.1uF } C 79900 69900 1 0 0 gnd.sym -T 79500 72100 9 10 1 0 0 0 3 +T 79500 72100 9 10 1 0 0 0 4 Adjust R135/R136 to sample DC rail without exceeding -3.3V ADC input range. +3.3V ADC input range. 100k +over 10k allows up to 36V. N 44200 64200 45400 64200 4 { T 44200 64300 5 10 1 1 0 0 1 -- 2.47.2