]> git.gag.com Git - hw/quantistrand/log
hw/quantistrand
5 days agotrim PCB on the DB connector end to improve mechanical fit master
Bdale Garbee [Sat, 4 Oct 2025 18:28:08 +0000 (12:28 -0600)]
trim PCB on the DB connector end to improve mechanical fit

4 weeks agofix text documenting external pin connections
Bdale Garbee [Wed, 10 Sep 2025 22:43:34 +0000 (16:43 -0600)]
fix text documenting external pin connections

4 weeks agocopper improvements to ensure solid ground connections at top of board fab-v3
Bdale Garbee [Wed, 10 Sep 2025 15:36:20 +0000 (09:36 -0600)]
copper improvements to ensure solid ground connections at top of board

4 weeks agodrop design to 2 layers
Bdale Garbee [Wed, 10 Sep 2025 15:30:08 +0000 (09:30 -0600)]
drop design to 2 layers

4 weeks agoupdate for use with QuantiMotor v2
Bdale Garbee [Wed, 10 Sep 2025 15:22:05 +0000 (09:22 -0600)]
update for use with QuantiMotor v2

10 months agorename, v3, add connector for a second pressure sensor
Bdale Garbee [Tue, 12 Nov 2024 01:06:14 +0000 (18:06 -0700)]
rename, v3, add connector for a second pressure sensor

3 years agoadd circuitry for optional open load in off test fab-v2
Bdale Garbee [Fri, 19 Nov 2021 02:49:34 +0000 (19:49 -0700)]
add circuitry for optional open load in off test

3 years agoroute complete, drc clean
Bdale Garbee [Wed, 17 Nov 2021 07:14:40 +0000 (00:14 -0700)]
route complete, drc clean

4 years agolose 3.3V net from schematic since we're not using it fab-v1
Bdale Garbee [Sun, 25 Oct 2020 20:49:35 +0000 (14:49 -0600)]
lose 3.3V net from schematic since we're not using it

4 years agochange screw order to put grounds between pyro and ADC inputs
Bdale Garbee [Sat, 24 Oct 2020 19:45:21 +0000 (13:45 -0600)]
change screw order to put grounds between pyro and ADC inputs

4 years agoadded Altus Metrum logo to silk
Bdale Garbee [Thu, 22 Oct 2020 05:45:54 +0000 (23:45 -0600)]
added Altus Metrum logo to silk

4 years agoadd high side power switch .. layout incomplete
Bdale Garbee [Thu, 22 Oct 2020 05:13:06 +0000 (23:13 -0600)]
add high side power switch .. layout incomplete

4 years agoadd screw terminal strip to layout, with silk annotations
Bdale Garbee [Thu, 22 Oct 2020 00:00:17 +0000 (18:00 -0600)]
add screw terminal strip to layout, with silk annotations

4 years agoclean up connector attributes so pref parts works
Bdale Garbee [Wed, 21 Oct 2020 17:57:49 +0000 (11:57 -0600)]
clean up connector attributes so pref parts works

4 years agoswitch to B-size title block, add output connector symbol
Bdale Garbee [Wed, 21 Oct 2020 17:43:33 +0000 (11:43 -0600)]
switch to B-size title block, add output connector symbol

4 years agocheck in blank daughter card as a starting point
Bdale Garbee [Wed, 21 Oct 2020 17:29:17 +0000 (11:29 -0600)]
check in blank daughter card as a starting point