From: Bdale Garbee Date: Wed, 5 Jun 2019 16:47:34 +0000 (-0600) Subject: switch to 1600psi pressure sensor on test stand X-Git-Url: https://git.gag.com/?a=commitdiff_plain;h=refs%2Fheads%2Ftf1-2019-hack;p=fw%2Faltos switch to 1600psi pressure sensor on test stand --- diff --git a/altoslib/AltosEepromRecordFireTwo.java b/altoslib/AltosEepromRecordFireTwo.java index e60497c3..4dd61bb5 100644 --- a/altoslib/AltosEepromRecordFireTwo.java +++ b/altoslib/AltosEepromRecordFireTwo.java @@ -48,12 +48,12 @@ public class AltosEepromRecordFireTwo extends AltosEepromRecord { public static double adc_to_pa(int adc) { // /* 1600psi sensor measured 2019.04.30, these values based on that */ -// double ADC_MIN = 405; -// double ADC_SLOPE = 1.95; + double ADC_MIN = 405; + double ADC_SLOPE = 1.95; /* 2500psi sensor measured 2019.04.30, these values based on that */ - double ADC_MIN = 392; - double ADC_SLOPE = 0.46; /* adc counts per psi */ +// double ADC_MIN = 392; +// double ADC_SLOPE = 0.46; /* adc counts per psi */ /* sensor is asserted to be linear 0 - max psi over ADC_MIN to ADC_MAX */ double raw = adc;