Documentation says they should be given values in milliseconds,
DEFAULT_HALT_TIMEOUT matches that too.
Change-Id: Ic1a30fa90f75b412c43fe50ba187d01c3d0a5fba
Signed-off-by: Paul Fertser <fercerpav@gmail.com>
Reviewed-on: http://openocd.zylin.com/1504
Tested-by: jenkins
Reviewed-by: Spencer Oliver <spen@spen-soft.co.uk>
int retval = parse_uint(CMD_ARGV[0], &ms);
if (ERROR_OK != retval)
return ERROR_COMMAND_SYNTAX_ERROR;
int retval = parse_uint(CMD_ARGV[0], &ms);
if (ERROR_OK != retval)
return ERROR_COMMAND_SYNTAX_ERROR;
- /* convert seconds (given) to milliseconds (needed) */
- ms *= 1000;
}
struct target *target = get_current_target(CMD_CTX);
}
struct target *target = get_current_target(CMD_CTX);
.handler = handle_wait_halt_command,
.mode = COMMAND_EXEC,
.help = "wait up to the specified number of milliseconds "
.handler = handle_wait_halt_command,
.mode = COMMAND_EXEC,
.help = "wait up to the specified number of milliseconds "
- "(default 5) for a previously requested halt",
+ "(default 5000) for a previously requested halt",
.usage = "[milliseconds]",
},
{
.usage = "[milliseconds]",
},
{
.handler = handle_halt_command,
.mode = COMMAND_EXEC,
.help = "request target to halt, then wait up to the specified"
.handler = handle_halt_command,
.mode = COMMAND_EXEC,
.help = "request target to halt, then wait up to the specified"
- "number of milliseconds (default 5) for it to complete",
+ "number of milliseconds (default 5000) for it to complete",
.usage = "[milliseconds]",
},
{
.usage = "[milliseconds]",
},
{