X-Git-Url: https://git.gag.com/?a=blobdiff_plain;f=doc%2Ftelemetrum.inc;h=fdb961d7c061923ba84979cccce60d8694d25495;hb=3735e1eb27afb873d60164a79a9e2769dc92b3a3;hp=3247db9553e214dd3d00c15966433380ba29788f;hpb=946faa1541f69c6cf2759c13760fa9bc16e2298e;p=fw%2Faltos diff --git a/doc/telemetrum.inc b/doc/telemetrum.inc index 3247db95..fdb961d7 100644 --- a/doc/telemetrum.inc +++ b/doc/telemetrum.inc @@ -43,9 +43,9 @@ |Terminal #|Terminal Name|Description |1 |Switch Output |Switch connection to flight computer |2 |Switch Input |Switch connection to positive battery terminal - |3 |Main + |Main pyro channel common connection to battery + + |3 |Main +++ |Main pyro channel common connection to battery +++ |4 |Main - |Main pyro channel connection to pyro circuit - |5 |Apogee + |Apogee pyro channel common connection to battery + + |5 |Apogee +++ |Apogee pyro channel common connection to battery +++ |6 |Apogee - |Apogee pyro channel connection to pyro circuit |=== @@ -62,14 +62,15 @@ stranded, into the GND hole just above the screw terminal strip and solder it in place. - Connecting the positive battery terminal to the pyro + Connecting the switched positive battery terminal to the pyro charges must be done separate from TeleMetrum, by soldering - them together or using some other connector. - + them together or using some other connector. Note that you + must include a switch in the positive lead from the pyro + battery for safety! The other lead from each pyro charge is then inserted into - the appropriate per-pyro channel screw terminal (terminal 4 for the - Main charge, terminal 6 for the Apogee charge). + the appropriate per-pyro channel screw terminal (terminal 4 + for the Main charge, terminal 6 for the Apogee charge). === Using an Active Switch with TeleMetrum