X-Git-Url: https://git.gag.com/?a=blobdiff_plain;f=doc%2Ftelemetrum.inc;h=7ef9876f6439eeff0dc91b5d011df7a2d1a9fa31;hb=a4039a60bbe972fd022699d62ab06a8f1bc4af69;hp=3247db9553e214dd3d00c15966433380ba29788f;hpb=946faa1541f69c6cf2759c13760fa9bc16e2298e;p=fw%2Faltos diff --git a/doc/telemetrum.inc b/doc/telemetrum.inc index 3247db95..7ef9876f 100644 --- a/doc/telemetrum.inc +++ b/doc/telemetrum.inc @@ -62,14 +62,15 @@ stranded, into the GND hole just above the screw terminal strip and solder it in place. - Connecting the positive battery terminal to the pyro + Connecting the switched positive battery terminal to the pyro charges must be done separate from TeleMetrum, by soldering - them together or using some other connector. - + them together or using some other connector. Note that you + must include a switch in the positive lead from the pyro + battery for safety! The other lead from each pyro charge is then inserted into - the appropriate per-pyro channel screw terminal (terminal 4 for the - Main charge, terminal 6 for the Apogee charge). + the appropriate per-pyro channel screw terminal (terminal 4 + for the Main charge, terminal 6 for the Apogee charge). === Using an Active Switch with TeleMetrum