Change reset cap to 0.1uF, mark LDO filter cap as a noload. The 1uF reset
[hw/telemetrum] / telemetrum.sch
index d56f70352ead7b7afe903fa26e0d528599919efe..b3dce534c40121943fa5ffbf7300b1309d8d9cfe 100644 (file)
@@ -7262,12 +7262,12 @@ T 57000 42800 5 10 1 1 180 0 1
 refdes=C36
 T 56600 42300 5 10 0 0 90 0 1
 symversion=0.1
-T 56500 42200 5 10 1 1 0 0 1
-value=0.001uF
+T 56700 42200 5 10 1 1 0 0 1
+value=0.1uF
 T 57500 42100 5 10 0 0 0 0 1
 footprint=0402
 T 57500 42100 5 10 0 0 0 0 1
-vendor_part_number=445-2651-1-ND
+vendor_part_number=399-3027-1-ND
 T 57500 42100 5 10 0 0 0 0 1
 vendor=digikey
 T 57500 42100 5 10 0 1 0 0 1
@@ -7759,15 +7759,15 @@ refdes=C38
 T 72000 68900 5 10 0 0 270 0 1
 symversion=0.1
 T 71500 68300 5 10 1 1 0 0 1
-value=0.1uF
+value=0.01uF
 T 71100 69100 5 10 0 0 270 0 1
-vendor_part_number=399-3027-1-ND
+vendor_part_number=709-1132-1-ND
 T 71100 69100 5 10 0 0 270 0 1
 footprint=0402
 T 71100 69100 5 10 0 0 270 0 1
 vendor=digikey
 T 71100 69100 5 10 0 1 270 0 1
-loadstatus=smt
+loadstatus=noload
 }
 C 68900 68800 1 0 0 TC2185.sym
 {