-
-.TP
-label \fBlabel\fR doesn't match labelstr \fBstr\fR
-Label \fBlabel\fR on the command line does not match the \fBlabelstr\fR regular expression \fBstr\fR from \fBamanda\&.conf\fR\&.
-
-.TP
-label \fBlabel\fR already on a tape
-Label \fBlabel\fR is already listed as an active \fBAmanda\fR tape\&.
-
-.TP
-no tpchanger specified in \fBpath\fR , so slot command invalid
-The command line has the \fBslot\fR parameter but the \fBamanda\&.conf\fR file in \fBpath\fR does not have a tape changer configured\&.
-
-.TP
-reading label \fBlabel\fR, tape is in another amanda configuration
-This tape appears to be a valid \fBAmanda\fR tape, but label does not match \fBlabelstr\fR for this configuration so it is probably part of a different \fBAmanda\fR configuration\&.
-
-.TP
-reading label \fBlabel\fR, tape is active
-Tape \fBlabel\fR appears to already be part of this \fBAmanda\fR configuration and active, i\&.e\&. has valid data on it\&.
-
-.TP
-no label found, are you sure \fBtape\fR is non\-rewinding?
-While checking that the label was written correctly, \fBamlabel\fR got an error that might be caused by mis\-configuring \fBAmanda\fR with a rewinding tape device name instead of a non\-rewinding device name for \fBtape\&.\fR
-
+.PP
+label \fIlabel\fR doesn\'t match labelstr \fIstr\fR
+.RS 4
+Label
+\fIlabel\fR
+on the command line does not match the
+\fIlabelstr\fR
+regular expression
+\fIstr\fR
+from
+\fIamanda\.conf\fR\.
+.RE
+.PP
+label \fIlabel\fR already on a tape
+.RS 4
+Label
+\fIlabel\fR
+is already listed as an active
+\fIAmanda\fR
+tape\.
+.RE
+.PP
+no tpchanger specified in \fIpath\fR , so slot command invalid
+.RS 4
+The command line has the
+\fBslot\fR
+parameter but the
+\fIamanda\.conf\fR
+file in
+\fIpath\fR
+does not have a tape changer configured\.
+.RE
+.PP
+reading label \fIlabel\fR, tape is in another amanda configuration
+.RS 4
+This tape appears to be a valid
+\fIAmanda\fR
+tape, but label does not match
+\fBlabelstr\fR
+for this configuration so it is probably part of a different
+\fIAmanda\fR
+configuration\.
+.RE
+.PP
+reading label \fIlabel\fR, tape is active
+.RS 4
+Tape
+\fIlabel\fR
+appears to already be part of this
+\fIAmanda\fR
+configuration and active, i\.e\. has valid data on it\.
+.RE
+.PP
+no label found, are you sure \fItape\fR is non\-rewinding?
+.RS 4
+While checking that the label was written correctly,
+\fBamlabel\fR
+got an error that might be caused by mis\-configuring
+\fIAmanda\fR
+with a rewinding tape device name instead of a non\-rewinding device name for
+\fItape\.\fR
+.RE