+\fI0\fR\. Debug level of the taper process
+.RE
+.PP
+\fBflush\-threshold\-dumped\fR int
+.RS 4
+Default:
+\fI0\fR\.
+\fIAmanda\fR
+will not begin writing data to a new volume until the amount of data on the holding disk is at least this percentage of the volume size\. In other words,
+\fIAmanda\fR
+will not begin until the inequality
+h < t \(mu d
+is satisfied, where
+h
+is the amount of data on the holding disk,
+t
+is the capacity of a volume, and
+d
+is this parameter, expressed as a percentage\.
+.sp
+Needless to say, your holding disk must be big enough that this criterion could be satisfied\. If the holding disk cannot be used for a particular dump (because, for example, there is no remaining holding space) then
+\fIAmanda\fR
+will disregard the constraint specified by this setting and start a new volume anyway\. Once writing to a volume has begun, this constraint is not applied unless and until a new volume is needed\.
+.sp
+The value of this parameter may not exceed than that of the
+\fBflush\-threshold\-scheduled\fR
+parameter\.
+.RE
+.PP
+\fBflush\-threshold\-scheduled\fR int
+.RS 4
+Default:
+\fI0\fR\.
+\fIAmanda\fR
+will not begin writing data to a new volume until the sum of the amount of data on the holding disk and the estimated amount of data remaining to be dumped during this run is at least this percentage of the volume size\. In other words,
+\fIAmanda\fR
+will not begin until the inequality
+h + s < t \(mu d
+is satisfied, where
+h
+is the amount of data on the holding disk,
+s
+is the total amount of data scheduled for this run but not dumped yet,
+t
+is the capacity of a volume, and
+d
+is this parameter, expressed as a percentage\.
+.sp
+Needless to say, your holding disk must be big enough that this criterion could be satisfied\. If the holding disk cannot be used for a particular dump (because, for example, there is no remaining holding space) then
+\fIAmanda\fR
+will disregard the constraint specified by this setting and start a new volume anyway\. Once writing to a volume has begun, this constraint is not applied unless and until a new volume is needed\.
+.sp
+The value of this parameter may not be less than that of the
+\fBflush\-threshold\-dumped\fR
+or
+\fBtaperflush\fR
+parameters\.
+.RE
+.PP
+\fBtaperflush\fR int
+.RS 4
+Default:
+\fI0\fR\. At the end of a run,
+\fIAmanda\fR
+will start a new tape to flush remaining data if there is more data on the holding disk at the end of a run than this setting allows; the amount is specified as a percentage of the capacity of a single volume\. In other words, at the end of a run,
+\fIAmanda\fR
+will begin a new tape if the inequality
+h < t \(mu f
+is satisfied, where
+h
+is the amount of data remaining on the holding disk from this or previous runs,
+t
+is the capacity of a volume, and
+f
+is this parameter, expressed as a percentage\.
+.sp
+The value of this parameter may not exceed that of the
+\fBflush\-threshold\-scheduled\fR
+parameter\.;
+\fBautoflush\fR
+must be set to \'yes\' if
+\fBtaperflush\fR
+is greater than 0\.