6 NameFragment is a local device name. If a remote device requires a local name, a local device replies the local device name;;help_end;;
\r
7 IDC_STATIC_NAME_FRAGMENT
\r
9 The HCI Baud Rate Index is the baud rate index of the HCI UART.;;help_end;;
\r
10 IDC_STATIC_HCI_BAUD_RATE_INDEX
\r
12 Set this parameter to enable UART H/W flow control(CTS).
\r
13 If MCU not support flow control, this parameter need be set as disable to disable this function.
\r
14 If Operation Pattern choose Manual Pattern, then this parameter will be set as disable.;;help_end;;
\r
15 IDC_STATIC_CTS_RTS_FLOW_CONTROL
\r
16 Check Rx Data Interval
\r
17 This parameter is used to set Check UART RX Data Interval.;;help_end;;
\r
18 IDC_STATIC_CHECK_RX_DATA_INTERVAL
\r
20 Enable / Disable UART RX IND ;;help_end;;
\r
21 IDC_STATIC_UART_RX_IND
\r
23 This parameter is used to set the operation pattern.;;help_end;;
\r
24 IDC_STATIC_OPERATION_PATTERN
\r
25 Configure Mode Timeout
\r
26 This parameter is used to set BM77 configure mode timeout.;;help_end;;
\r
27 IDC_STATIC_CONFIGURE_MODE_TIMEOUT
\r
28 Power On Standby Time
\r
29 The standby time duration after power on. device shall enter save power mode when time is up.
\r
30 0x00~0xFE: Standby time parameters.
\r
31 0xFF: Disable auto power_off function(enter S2 mode);;help_end;;
\r
32 IDC_STATIC_POWER_ON_STANDBY_TIME
\r
33 Disconnection Standby Time
\r
34 The standby time duration after disconnection.
\r
35 Device shall enter save power mode when time is up.
\r
36 0x00~0xFE: Standby time parameters.
\r
37 0xFF: Disable auto power_off function(enter S2 mode);;help_end;;
\r
38 IDC_STATIC_REMOTE_DISCONNECT_STANDBY_TIME
\r
39 Wakeup Externel MCU Wait Time
\r
40 Waiting time duration to wake MCU up.;;help_end;;
\r
41 IDC_STATIC_WAKEUP_EXTERNAL_MCU_WAIT_TIME
\r
43 This parameter is used to decide BLEDK3 can be waken up from shutdown mode by wakeup pin or not.;;help_end;;
\r
44 IDC_STATIC_WAKEUP_PIN_OPTION
\r
45 Bluetooth 4.0 BLE Security
\r
46 This parameter is uesd to set BLE Security.;;help_end;;
\r
47 IDC_STATIC_BLE_SECURITY
\r
48 Trust Device Connection
\r
49 This parameter is used to enable/disable trust (paired) device connection.;;help_end;;
\r
50 IDC_STATIC_TRUST_DEVICE_CONNECTION
\r
52 This parameter is used to config IO Capability;;help_end;;
\r
53 IDC_STATIC_IO_CAPABILITY
\r
54 BLE User Confirm Option
\r
55 This parameter is used to enable/disable LE user confirm refer to passkey. And passkey must set 6 digits if enable.;;help_end;;
\r
56 IDC_STATIC_BLE_USER_CONFIRM_OPTION
\r
58 The Passkey which is six byte ASCII code and be used in passkey confirm.;;help_end;;
\r
60 LE Secure Connections
\r
61 This parameter is used to enable/disable LE Secure Connections.;;help_end;;
\r
62 IDC_STATIC_LE_SECURE_CONNECTIONS
\r
63 Link Manager Version
\r
64 This parameter is used to choose Link Manager Version is BT4.0 or BT4.2.;;help_end;;
\r
65 IDC_STATIC_LINK_MANAGER_VERSION
\r
66 Data Length Extension
\r
67 This parameter is used to enable/disable Data Length Extension.;;help_end;;
\r
68 IDC_STATIC_DATA_LENGTH_EXTENSION
\r
70 The 16 ASCII characters for the customers' version control code. The download tool can check by this code and reject to download the eFlash if it's mismatch.;;help_end;;
\r
71 IDC_STATIC_FOOTPRINT
\r
72 Link Quality Detection
\r
73 Enable/Disable link quality detection.
\r
74 The RF_Tx_Power_Control_feature will be disabled if Enable this parameter.;;help_end;;
\r
75 IDC_STATIC_LINK_QUALITY_DETECTION
\r
76 RSSI Normal Threshold
\r
77 This parameter is used to set RSSI normal threshole value;;help_end;;
\r
78 IDC_STATIC_RSSI_NORMAL_THRESHOLD
\r
80 This parameter is used to set RSSI weak threshole value;;help_end;;
\r
81 IDC_STATIC_RSSI_WEAK_THRESHOLD
\r
82 Battery Detection Interval
\r
83 Thie parameter is uesd to set battery detection interval;;help_end;;
\r
84 IDC_STATIC_BATTERY_DETECTION
\r
86 High battery level;;help_end;;
\r
87 IDC_STATIC_HIGH_BATTERY_LEVEL
\r
88 Normal Battery Level
\r
89 This parameter is defined a normal voltage value of a battery. When the voltage is lower than this value,the device will start low battery warring.;;help_end;;
\r
90 IDC_STATIC_NORMAL_BATTERY_LEVEL
\r
92 This parameter is defined a low voltage value of a battery. When the voltage is lower than this value, the device will shutdown.;;help_end;;
\r
93 IDC_STATIC_LOW_BATTERY_LEVEL
\r
94 Dangerous Battery Level
\r
95 Dangerout battery level;;help_end;;
\r
96 IDC_STATIC_DANGEROUS_BATTERY_LEVEL
\r
97 Low Battery Into Shutdown Time
\r
98 This parameter is used to set the waiting time befor enter into shutdown mode if low battery happens.
\r
99 (0x00: Disable enter into shutdown mode when low battery happens);;help_end;;
\r
100 IDC_STATIC_LOW_BATTERY_INTO_POWER_DOWN_TIME
\r
102 The RF_Class is the RF class type.;;help_end;;
\r
103 IDC_STATIC_RF_CLASS
\r
105 Set the function mapping to the GPIO P3_6;;help_end;;
\r
108 Set the function mapping to the GPIO P1_0;;help_end;;
\r
111 Set the function mapping to the GPIO P0_0;;help_end;;
\r
114 Set the function mapping to the GPIO P3_1;;help_end;;
\r
117 Set the function mapping to the GPIO P3_2;;help_end;;
\r
120 Set the function mapping to the GPIO P3_3;;help_end;;
\r
123 Set the function mapping to the GPIO P3_4;;help_end;;
\r
126 Set the function mapping to the GPIO P0_7;;help_end;;
\r
129 Set the function mapping to the GPIO P1_1;;help_end;;
\r
132 Set the function mapping to the GPIO P2_2;;help_end;;
\r
135 Set the function mapping to the GPIO P2_4;;help_end;;
\r
138 Set the function mapping to the GPIO P3_5;;help_end;;
\r
141 Set the function mapping to the GPIO P1_2;;help_end;;
\r
144 Set the function mapping to the GPIO P1_3;;help_end;;
\r
147 Set the function mapping to the GPIO P1_6;;help_end;;
\r
150 Set the function mapping to the GPIO P1_7;;help_end;;
\r
152 RF Active IND MCU Include
\r
153 This parameter is used to choose the indication type of RF active time.;;help_end;;
\r
154 IDC_STATIC_RF_ACTIVE_IND_MCU_INCLUDE
\r
155 LE Connection Parameter Update Request
\r
156 The LE Connection Setting will be assigned by Remote if select Disable.
\r
157 It will sent update request if select Enable.;;help_end;;
\r
158 IDC_STATIC_LE_CONNECTION_PARAMETER_UPDATE
\r
159 Min LE Connection Interval
\r
160 This parameter is used to set LE min connection interval;;help_end;;
\r
161 IDC_STATIC_MIN_LE_CONNECTION_INTERVAL
\r
162 Max LE Connection Interval
\r
163 This parameter is used to set LE max connection interval;;help_end;;
\r
164 IDC_STATIC_MAX_LE_CONNECTION_INTERVAL
\r
166 This parameter is used to set LE slave latency;;help_end;;
\r
167 IDC_STATIC_LE_SLAVE_LATENCY
\r
168 LE Supervision Timeout
\r
169 This parameter is used to set LE supervision timeout ;;help_end;;
\r
170 IDC_STATIC_LE_SUPERVISION_TIMEOUT
\r
171 LE Fast Advertising Interval
\r
172 This parameter is uesd to set LE fast advertising interval;;help_end;;
\r
173 IDC_STATIC_LE_FAST_ADVERTISING_INTERVAL
\r
174 LE Reduced Power Advertising Interval
\r
175 This parameter is uesd to set LE reduced power advertising interval;;help_end;;
\r
176 IDC_STATIC_LE_REDUCED_POWER_ADVERTISING
\r
177 LE Fast Advertising Timeout
\r
178 This parameter is uesd to set LE fast advertising timeout value;;help_end;;
\r
179 IDC_STATIC_LE_FAST_ADVERTISING_TIMEOUT
\r
180 Power On LE Reduced Power Advertising Timeout
\r
181 This parameter is uesd to show Power On LE Reduced Power Advertising timeout value.
\r
182 Power On LE Reduced Power Advertising timeout = Power on Standby Time - LE Fast Advertising Timeout.;;help_end;;
\r
183 IDC_STATIC_POWER_ON_LE_REDUCED_POWER_ADVERTISING_TIMEOUT
\r
184 Disconnection LE Reduced Power Advertising Timeout
\r
185 This parameter is uesd to show Disconnection LE Reduced Power Advertising Timeout value.
\r
186 Disconnection LE Reduced Power Advertising Timeout = Disconnection Standby Time - LE Fast Advertising Timeout;;help_end;;
\r
187 IDC_STATIC_DISCONNECTION_LE_REDUCED_POWER_ADVERTISING_TIMEOUT
\r
188 Advertising Prefered Power Level
\r
189 Prefered Tx power level when advertising.;;help_end;;
\r
190 IDC_STATIC_ADVERTISING_TX_POWER_LEVEL
\r
191 Connected Prefered Power Level
\r
192 Prefered Tx power level when connected.;;help_end;;
\r
193 IDC_STATIC_CONNECTED_TX_POWER_LEVEL
\r
194 Advertising Data Setting
\r
195 This parameter is uesd to set advertising data.
\r
196 Reference RSSI - This value represents the measured strength of the beacon from one meter away and is used during ranging.;;help_end;;
\r
197 IDC_STATIC_ADVERTISING_DATA_SETTING
\r
198 Scan Response Data Setting
\r
199 This parameter is uesd to set scan response data;;help_end;;
\r
200 IDC_STATIC_SCAN_RESPONSE_DATA_SETTING
\r
202 This is the LED display method.;;help_end;;
\r
203 IDC_STATIC_LED_TYPE
\r
205 This the LED on time for flash.;;help_end;;
\r
206 IDC_STATIC_LED_ON_TIME
\r
208 This the LED off time for flash.;;help_end;;
\r
209 IDC_STATIC_LED_OFF_TIME
\r
211 This is the number of the flash times for a round.;;help_end;;
\r
212 IDC_STATIC_LED_COUNT
\r
214 This is the time interval for a round.;;help_end;;
\r
215 IDC_STATIC_LED_INTERVAL
\r
217 This is the LED display method.;;help_end;;
\r
218 IDC_STATIC_LED_TYPE
\r
220 This the LED on time for flash.;;help_end;;
\r
221 IDC_STATIC_LED_ON_TIME
\r
223 This the LED off time for flash.;;help_end;;
\r
224 IDC_STATIC_LED_OFF_TIME
\r
226 This is the number of the flash times for a round.;;help_end;;
\r
227 IDC_STATIC_LED_COUNT
\r
229 This is the time interval for a round.;;help_end;;
\r
230 IDC_STATIC_LED_INTERVAL
\r
232 This is the LED display method.;;help_end;;
\r
233 IDC_STATIC_LED_TYPE
\r
235 This the LED on time for flash.;;help_end;;
\r
236 IDC_STATIC_LED_ON_TIME
\r
238 This the LED off time for flash.;;help_end;;
\r
239 IDC_STATIC_LED_OFF_TIME
\r
241 This is the number of the flash times for a round.;;help_end;;
\r
242 IDC_STATIC_LED_COUNT
\r
244 This is the LED display method.;;help_end;;
\r
245 IDC_STATIC_LED_TYPE
\r
247 This the LED on time for flash.;;help_end;;
\r
248 IDC_STATIC_LED_ON_TIME
\r
250 This the LED off time for flash.;;help_end;;
\r
251 IDC_STATIC_LED_OFF_TIME
\r
253 This is the number of the flash times for a round.;;help_end;;
\r
254 IDC_STATIC_LED_COUNT
\r
256 This parameter is uesd to set LED warning time interval if low battery happens;;help_end;;
\r
257 IDC_STATIC_LOW_BATTERY_LED_INTERVAL
\r
259 LED brightness setting.;;help_end;;
\r
260 IDC_STATIC_LED1_BRIGHTNESS
\r
262 Enable/Disable Beacon function;;help_end;;
\r
263 IDC_STATIC_BEACON_FEATURE
\r
265 Enable/Disable Beacon admin mode;;help_end;;
\r
266 IDC_STATIC_BEACON_ADMIN_MODE
\r
267 Beacon Admin Timeout
\r
268 This parameter is used to configure Beacon admin timeout value
\r
269 0x00: Disable Beacon Admin Feature;;help_end;;
\r
270 IDC_STATIC_BEACON_ADMIN_TIMEOUT
\r
271 Beacon In Connection
\r
272 If Beacon In Connect is Enable, beacon advertising will stop when LE connection is established.;;help_end;;
\r
273 IDC_STATIC_BEACON_IN_CONNECTION
\r
274 Beacon Advertising Interval
\r
275 This parameter is used to confirue advertising interval for Beacon using;;help_end;;
\r
276 IDC_STATIC_BEACON_ADVERTISING_INTERVAL
\r
277 Beacon Advertising Data Length
\r
278 This paraeter is used to configure advertising data len for Beacon using;;help_end;;
\r
279 IDC_STATIC_BEACON_ADVERTISING_DATA_LENGTH
\r
280 Beacon Advertising Data
\r
281 This paraeter is used to configure advertising data for Beacon using;;help_end;;
\r
282 IDC_STATIC_BEACON_ADVERTISING_DATA
\r
284 This parameter is used to config Secret key for Beacon Admin usage;;help_end;;
\r
285 IDC_STATIC_BEACON_SECRET_KEY