than the primary so that both pyrotechnic charges don't fire
simultaneously.
</para>
- <para>
- To set the main deployment altitude, use the 'c m' command.
- As with all 'c' sub-commands, follow this with a 'c w' to write the
- change to the parameter block in the on-board DataFlash chip.
- </para>
</section>
</section>
- <section>
- <title>Calibration</title>
- <para>
- There are only two calibrations required for a TeleMetrum board, and
- only one for TeleDongle and TeleMini.
- </para>
- <section>
- <title>Radio Frequency</title>
- <para>
- The radio frequency is synthesized from a clock based on the 48 MHz
- crystal on the board. The actual frequency of this oscillator must be
- measured to generate a calibration constant. While our GFSK modulation
- bandwidth is wide enough to allow boards to communicate even when
- their oscillators are not on exactly the same frequency, performance
- is best when they are closely matched.
- Radio frequency calibration requires a calibrated frequency counter.
- Fortunately, once set, the variation in frequency due to aging and
- temperature changes is small enough that re-calibration by customers
- should generally not be required.
- </para>
- <para>
- When the radio calibration value is changed, the radio
- frequency value is reset to the same value, so you'll need
- to recompute and reset the radio frequency value using the
- new radio calibration value.
- </para>
- </section>
- <section>
- <title>TeleMetrum Accelerometer</title>
- <para>
- The TeleMetrum accelerometer we use has its own 5 volt power supply and
- the output must be passed through a resistive voltage divider to match
- the input of our 3.3 volt ADC. This means that unlike the barometric
- sensor, the output of the acceleration sensor is not ratio-metric to
- the ADC converter, and calibration is required. We also support the
- use of any of several accelerometers from a Freescale family that
- includes at least +/- 40g, 50g, 100g, and 200g parts. Using gravity,
- a simple 2-point calibration yields acceptable results capturing both
- the different sensitivities and ranges of the different accelerometer
- parts and any variation in power supply voltages or resistor values
- in the divider network.
- </para>
- <para>
- To calibrate the acceleration sensor, use the 'c a 0' command. You
- will be prompted to orient the board vertically with the UHF antenna
- up and press a key, then to orient the board vertically with the
- UHF antenna down and press a key.
- As with all 'c' sub-commands, follow this with a 'c w' to write the
- change to the parameter block in the on-board DataFlash chip.
- </para>
- <para>
- The +1g and -1g calibration points are included in each telemetry
- frame and are part of the header extracted by ao-dumplog after flight.
- Note that we always store and return raw ADC samples for each
- sensor... nothing is permanently "lost" or "damaged" if the
- calibration is poor.
- </para>
- <para>
- In the unlikely event an accel cal that goes badly, it is possible
- that TeleMetrum may always come up in 'pad mode' and as such not be
- listening to either the USB or radio link. If that happens,
- there is a special hook in the firmware to force the board back
- in to 'idle mode' so you can re-do the cal. To use this hook, you
- just need to ground the SPI clock pin at power-on. This pin is
- available as pin 2 on the 8-pin companion connector, and pin 1 is
- ground. So either carefully install a fine-gauge wire jumper
- between the two pins closest to the index hole end of the 8-pin
- connector, or plug in the programming cable to the 8-pin connector
- and use a small screwdriver or similar to short the two pins closest
- to the index post on the 4-pin end of the programming cable, and
- power up the board. It should come up in 'idle mode' (two beeps).
- </para>
- </section>
- </section>
</chapter>