-== TeleMini v2.0
-
-       .TeleMini v2.0 Board
-       image::telemini-v2-top.jpg[width="5.5in"]
-      
-       TeleMini v2.0 is 0.8 inches by 1½ inches. It adds more
-       on-board data logging memory, a built-in USB connector and
-       screw terminals for the battery and power switch. The larger
-       board fits in a 24mm coupler. There's also a battery connector
-       for a LiPo battery if you want to use one of those.
-
-       === TeleMini v2.0 Screw Terminals
-       
-               TeleMini v2.0 has two sets of four screw terminals on the end of the
-               board opposite the telemetry antenna. Using the picture
-               above, the top four have connections for the main pyro
-               circuit and an external battery and the bottom four have
-               connections for the apogee pyro circuit and the power
-               switch. Counting from the left, the connections are as follows:
-
-               .TeleMini v2.0 Screw Terminals
-               [options="header",grid="all",cols="2,3,10"]
-               |====
-               |Terminal #|Terminal Name|Description
-               |Top 1
-               |Main -
-               |Main pyro channel connection to pyro circuit
-             
-               |Top 2
-               |Main +
-               |Main pyro channel common connection to battery +
-             
-               |Top 3
-               |Battery +
-               |Positive external battery terminal
-             
-               |Top 4
-               |Battery -
-               |Negative external battery terminal
-             
-               |Bottom 1
-               |Apogee -
-               |Apogee pyro channel connection to pyro circuit
-             
-               |Bottom 2
-               |Apogee +
-               |Apogee pyro channel common connection to battery +
-             
-               |Bottom 3
-               |Switch Output
-               |Switch connection to flight computer
-             
-               |Bottom 4
-               |Switch Input
-               |Switch connection to positive battery terminal
-               |====
-
-       === Connecting A Battery To TeleMini v2.0
-
-               There are two possible battery connections on TeleMini
-               v2.0. You can use either method; both feed through
-               the power switch terminals.
-
-               One battery connection is the standard Altus Metrum
-               white JST plug. This mates with single-cell Lithium
-               Polymer batteries sold by Altus Metrum.
-
-               The other is a pair of screw terminals marked 'Battery
-               +' and 'Battery -'. Connect a battery from 4 to 12
-               volts to these terminals, being careful to match polarity.
-
-       === Charging Lithium Batteries
-
-               Because TeleMini v2.0 allows for batteries other than
-               the standard Altus Metrum Lithium Polymer cells, it
-               cannot incorporate a battery charger
-               circuit. Therefore, when using a Litium Polymer cell,
-               you'll need an external charger. These are available
-               from Altus Metrum, or from Spark Fun.
-
-       === Using a Separate Pyro Battery with TeleMini v2.0
-       
-               As described above, using an external pyro battery involves
-               connecting the negative battery terminal to the flight
-               computer ground, connecting the positive battery terminal to
-               one of the igniter leads and connecting the other igniter
-               lead to the per-channel pyro circuit connection.
-
-               To connect the negative pyro battery terminal to TeleMini
-               ground, connect it to the negative external battery
-               connection, top terminal 4.
-
-               Connecting the positive battery terminal to the pyro
-               charges must be done separate from TeleMini v2.0, by soldering
-               them together or using some other connector.
-
-               The other lead from each pyro charge is then inserted into
-               the appropriate per-pyro channel screw terminal (top
-               terminal 1 for the Main charge, bottom terminal 1 for the
-               Apogee charge).
-
-       === Using an Active Switch with TeleMini v2.0
-       
-               As explained above, an external active switch requires three
-               connections, one to the positive battery terminal, one to
-               the flight computer positive input and one to ground. Use
-               the negative external battery connection, top terminal 4 for
-               ground.
-
-               The positive battery terminal is available on bottom
-               terminal 4, the positive flight computer input is on the
-               bottom terminal 3.